Keep Downtime to a Minimum
When you need fast UV surface sanitizing between shifts, look no further than this Induction UVC High Bay Disinfection Fixture. Capable of sanitizing in 4 minutes at a 20-foot installation height or 12 minutes at a 40-foot installation height (see below chart), these powerful fixtures are designed to keep downtime to a minimum. An additional benefit of induction technology is its long life span: 100,000 hours on average. This makes it extremely low-maintenance—always a boon when dealing with high-ceiling fixtures.
Safety
Each fixture has a motion sensor built in to automatically turn the light off if motion is detected. We recommend that UVC fixtures be installed on a circuit separate from your regular lighting. We also recommend a timer switch for the main controller. And while each fixture comes standard with a built-in motion sensor, for additional safety we also recommend grouping fixtures on a control circuit incorporating a motion sensor.
Mounting Height | Irradiance/Second | Exposure Time Required* | Beam Length | Beam Width |
10 ft | 166.92 uW/cm² | 1.2 minutes | 6.3 ft | 6.3 ft |
12 ft | 121.34 uW/cm² | 1.65 minutes | 7.6 ft | 7.6 ft |
15 ft | 82.86 uW/cm² | 2.5 minutes | 9.5 ft | 9.5 ft |
18 ft | 61.15 uW/cm² | 3.3 minutes | 11.46 | 11.46 |
20 ft | 51.48 uW/cm² | 3.9 minutes | 12.74 ft | 12.74 ft |
22.5 ft | 42.61 uW/cm² | 4.7 minutes | 14.34 ft | 14.34 ft |
25 ft | 36.06 uW/cm² | 5.6 minutes | 15.92 ft | 15.92 ft |
28 ft | 30.25 uW/cm² | 6.7 minutes | 17.84 ft | 17.84 ft |
30 ft | 27.21 uW/cm² | 7.4 minutes | 19.11 ft | 19.11 ft |
32.5 ft | 24.11 uW/cm² | 8.3 minutes | 20.7 ft | 20.7 ft |
35 ft | 21.59 uW/cm² | 9.3 minutes | 22.3 ft | 22.3 ft |
40 ft | 17.75 uW/cm² | 11.3 minutes | 25.5 ft | 25.5 ft |
*Exposure time is based off of total irradiance. The above calculations are based on 12mJ total exposure. This level of exposure deactivates most organisms. |
Warning and Disclaimer: UVC radiation can cause skin burns and eye injuries that may appear hours after exposure has occurred. Avoid direct skin exposure to UVC radiation and never look directly into a UVC light source, even briefly. Inappropriate and improper use of the UV-C products could be dangerous and harmful. Always keep the products away from and out of reach of children. We recommend ANSI Z87.1-1989 eye/face protection, long pants and sleeves, and disposable nitrile gloves when working with or around exposed UV lamps. You are cautioned not to tamper with factory settings.
Wavelength | 254 nm peak |
Wattage(s) | 300W |
Average Lamp Life | 100,000 hours |
Occupancy Sensor | Yes |
Safety Features | Microwave motion sensor |
Base Type | Fixture |
Light Type | Germicidal UV (UVC) |
Input Voltage | 120-277V AC - 2.5A @ 120V 1.25A @ 240V 1.08A @ 277V |
Certification | EPA |